EasyManua.ls Logo

Allen-Bradley 1756-M08SE - Mirror Image Ry Orientation; Rx Axis Position in Mirror Non-Flip and Mirror Flip Regions

Allen-Bradley 1756-M08SE
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4
Geometries with orientation support
196 Rockwell Automation Publication MOTION-UM002F-EN-P - February 2018
Configure a Delta J1J2J3J4J5 coordinate system on page 161
Ry is limited to +/- 90 per Euler angle rules. Refer to Orientation Specification
for information about XYZ Fixed angles and Euler Angles Representation. Mirror
image refers to the way the Ry position trend looks with respect to +/- 90 .
When the J5 axis position is in the range of -90.0 > J5 > +90.0 , the Ry axis
position correlates inversely to J5 axis position. This range of operation is referred
to as the mirror non-flip region, and is similar in behavior to the Rz/J4 transform
position relationship.
When the J5 axis crosses the ninety degree boundary, the Ry axis position no
longer tracks the inverse of J5. Instead the Ry position reflects a positive
correlation with J5. This range of operation is referred to as mirror flip region.
See also
Rx axis position in mirror non-flip and flip regions on page 196
Rz axis position in mirror non-flip and flip regions on page 197
Orientation specification on page 123
For certain geometries, such as the Delta J1J2J3J4J5, there is no direct control
over the Rx axis. Instead, the value of Rx can be one of two discrete values
depending on the J5/Ry position:
Region Rx position
Mirror non-flip
180.0
Mirror flip
0.0
Mirror image Ry orientation
Rx axis position in mirror
non-flip and mirror flip regions

Table of Contents

Related product manuals