Publication 2707-UM005B-EN-P
Transferring Applications 4-9
The Communication Port Selection screen appears. You will not
see the following screen if a communication port was specified
during DPS installation.
10. Highlight the serial port on your computer that is connected to
the MicroView (COMM1 or COMM2) and press [Return].
11. When communication is established, the upload begins and the
following screen shows the progress of the upload operation.
Note: If a communication link does not occur in 60 seconds,
you get an error message. Check cable connections and verify
that the MicroView is in the Program Mode.