Chapter 9 Communication instructions
206 Rockwell Automation Publication 2080-RM001D-EN-E - February 2015
Parameter
Parameter
type
Data type Description
Error Output BOOL TRUE - When error occurs.
FALSE - No error.
ErrorID Output UINT Show the error code when message transfer failed.
See Modbus2 error codes on page 208.
SuberrorID Output UINT Used to verify status bits:
Bit 0: EN Enable
Bit 1: EW Enable Wait
Bit 2: ST Start
Bit 3: ER Error
Bit 4: DN Done
Other bits are reserved.
StatusBits Output UINT Sub Error code value when Error is TRUE.
When a MSG is triggered, or re-triggered, a previously set SubErrorID is cleared.