Chapter 12 Data conversion instructions
288 Rockwell Automation Publication 2080-RM001D-EN-E - February 2015
ANY_TO_SINT converts a value to a Short Integer value.
Arguments
Parameter Parameter Type Data Type Description
EN Input BOOL Function enable.
When Enable = TRUE, execute the conversion to the 8-bit Short Integer
computation.
When Enable = FALSE, there is no computation.
Applies only to LD programs.
i1 Input BOOL - USINT - BYTE - INT - UINT -
WORD - DINT - UDINT - DWORD -
LINT - ULINT - LWORD - REAL - LREAL
- TIME - DATE - STRING
Any non-Short Integer value.
o1 Output SINT A Short Integer value.
ENO Output BOOL Enable out.
Applies only to LD programs.
ANY_TO_SINT operator ST language example
(* ST Equivalence: *)
bres := ANY_TO_SINT (true);
(* bres is 1 *)
tres := ANY_TO_SINT (t#0s46ms);
(* tres is 46 *)
mres := ANY_TO_SINT ('0198');
(* mres is 198 *)