Chapter 12 Data conversion instructions
284 Rockwell Automation Publication 2080-RM001D-EN-E - February 2015
ANY_TO_LINT converts a value to a 64-bit Long Integer value.
Arguments
Parameter Parameter Type Data Type Description
EN Input BOOL Function enable.
When Enable = TRUE, execute the conversion to the 64-bit Long Integer computation.
When Enable = FALSE, there is no computation.
Applies only to LD programs.
i1 Input BOOL - SINT - USINT -
BYTE - INT - UINT - WORD
- DINT - UDINT - DWORD
- LINT - ULINT - LWORD -
REAL - LREAL - TIME -
DATE - STRING
Any value other than a Long Integer.
o1 Output LINT A 64-bit Long Integer value.
ENO Output BOOL Enable out.
Applies only to LD programs.
ANY_TO_LINT operator ST language example
(* ST Equivalence: *)
bres := ANY_TO_LINT (true);
tres := ANY_TO_LINT (t#0s46ms);
mres := ANY_TO_LINT ('0198');