Motion control instructions Chapter 17
Rockwell Automation Publication 2080-RM001D-EN-E - February 2015 519
MC_WriteBoolParameter modifies the value of a vendor specific parameter of
type BOOL.
MC_WriteBoolParameter operation
The parameters set by the MC_WriteBoolParameter function block are only
applied to the application temporarily. They are overwritten by the permanent
settings, which are configured by the user in Connect Component Workbench
Motion Configuration, when the controller is switched from PRG to RUN, or
when the controller power is cycled.