Input/Output instructions Chapter 15
Rockwell Automation Publication 2080-RM001D-EN-E - February 2015 393
PLUGIN_INFO reads the Plug-in Generic Module Information. It can read any
Plug-in module information except for 2080-MEMBAK-RTC modules. When a
Plug-in Generic Module is not present, all values return to zero (0).
Arguments
Parameter Parameter type
Data
type
Description
Enable Input BOOL Function block enable.
When Enable = TRUE, execute P_IM information read.
When Enable = FALSE, the function block is not executed. All output data values are reset to 0.
SlotID Input UINT Plug-in slot number.
Slot ID = 1,2,3,4,5 (starting with far left slot = 1).
ModID Output UINT Plug-in Generic Module physical ID.
VendorID Output UINT Plug-in Generic Module vendor ID.
For Allen Bradley products, the vendor ID = 1.
ProductType Output UINT Plug-in Generic Module product type.
ProductCode Output UINT Plug-in Generic Module product code.
ModRevision Output UINT Plug-in Generic Module revision information.
ENO Output BOOL Enable out.
Applies only to LD programs.