Chapter 14 High-Speed Counter (HSC) instructions
354 Rockwell Automation Publication 2080-RM001D-EN-E - February 2015
Results
In this example, the PLS variable has a dimension of [1..4]. This means that
the HSC can have four pairs of High and Low Presets.
High Presets should always be set lower than the OFSetting and the
Low Preset should always be greater than the UFSetting.
The HscHPOutPut and HscLPOutPut values will determine which
outputs will be turned on when a High Preset or Low Preset is reached.