104 Rockwell Automation Publication 6000-UM002E-EN-P - April 2018
Chapter 5 Preventative Maintenance and Component Replacement
Figure 36 - Lift Cart Procedure
Install Power Module
1. You can use the lift cart to move and position the Power Module to the 
appropriate location in the cabinet.
2. Push the Power Module slowly along the guide rails until it cannot be 
pushed in further.
Hand Crank
Foot Crank
Pressure Release Knob
1. Check the lift tray before use to ensure the tray 
can be raised and lowered smoothly.
2. Rotate the Pressure Release Knob 
counterclockwise to ensure that the tray is in 
the lowest position.
3. Move the Power Module on the tray and lift 
the module to the appropriate height using the 
Foot Crank and complete the installation.
4. Rotate the Pressure Release Knob 
counterclockwise to lower the tray to its 
original position.
5. Repeat steps 1...4 to complete the installation 
for all the Power Modules.
The Foot Crank raises the lift tray faster than 
the Hand Crank. Use this to raise the Power 
Module to just below the tray assembly in 
the drive. Use the Hand Crank for final 
precise positioning.
Lift tray
Release 
pressure in 
cylinder
Seal 
pressure in 
cylinder
The Power Module should be handled carefully. After removing the packaging, 
inspect the Power Module to confirm there is no damage and moisture.