Rockwell Automation Publication 6000-UM002E-EN-P - April 2018 80
Parameters and Function Codes Chapter 4
P378 Amplitude At Second Point for 5
Point VF
0 100 10 10 10 10 10 10 10 10 10 10 10 10 % Offline Y Y Y
P379 Frequency At Third Point for 5 Point
VF
10 100404040404040404040404040%OfflineYY
P380 Amplitude At Third Point for 5 Point
VF
0 100 27 27 27 27 27 27 27 27 27 27 27 27 % Offline Y Y
P381 Frequency At Fourth Point for 5
Point VF
10 100606060606060606060606060%OfflineYY
P382 Amplitude At Fourth Point for 5
Point VF
0 100 45 45 45 45 45 45 45 45 45 45 45 45 % Offline Y Y
P383 Frequency At Fifth Point for 5 Point
VF
10 100808080808080808080808080%Offline Y
P384 Amplitude At Fifth Point for 5 Point
VF
0 100 70 70 70 70 70 70 70 70 70 70 70 70 % Offline Y Y
P385 Deceleration Process Enable
0 = Disable
1 = Enable
0 1000000000000 OfflineYY
P386 Deceleration Time 1 1.0 3276.7 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 s On/Off Y Y
P387 Deceleration Frequency 1 0 75 30 30 30 30 30 30 30 30 30 30 30 30 On/Off Y Y
P388 Deceleration Time 2 1.0 3276.7 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 s On/Off Y Y
P389 Deceleration Frequency 2 0 75 20 20 20 20 20 20 20 20 20 20 20 20 On/Off Y Y
P390 Deceleration Time 3 1.0 3276.7 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 s On/Off Y Y
P391 Deceleration Frequency 3 0 75 10 10 10 10 10 10 10 10 10 10 10 10 On/Off Y Y
P392 Deceleration Time 4 1.0 3276.7 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 s On/Off Y Y
P393 Flying Start Compensation Enable
0 = Disable
1 = Enable
0 1111111111111 On/OffYY
P394 Flying Start Compensation Current
Threshold
0.00 399.99 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 On/Off Y Y
P395 Flying Start Compensation
Frequency Reduce Speed
10 16384 50 50 50 50 50 50 50 50 50 50 50 50 On/Off Y Y
P396 Deceleration Control Enable
0 = Disable
1 = Enable
0 1111111111111 On/OffYY
P397 DC Bus Lower Limit 0 32767 700 700 950 950 900 900 1000 950 950 1000 1000 1000 V On/Off Y Y
No. Name Min. Max. Default Values Units Modify
Root
Access
2300V 2400V 3000V 3300V 4000V 4160V 6000V 6300V 6600V 6900V 10000V 11000V U S R