EasyManua.ls Logo

Alpine PXA-H800 - Adjusting the Time Correction Automatically; Adjusting for Road Noise

Alpine PXA-H800
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
From
a
PC
Adjusting
the
Time
Correction
Automatically
(Auto
TCR)
A vehicle poses a unique listening environment. Speaker distances vary
widely to each listening position. These special conditions can
be
overcome using the included microphone and the powerful
measurement system in this processor. The processor measures and
analyzes data automatically to optimize time correction for each speaker
and listening position selected.
1 Preparing for measurement.
Park the vehicle
in
a quiet location.
Close doors, windows, sunroof, etc.
Turn the air-conditioner and heater
OFF.
Turn off the engine of the vehicle.
2 Preparing the microphone.
Place the microphone at the listening position (driver's seat,
etc.). A camera tripod is recommended for this purpose.
The microphone should be placed
at
shoulder height.
When you save the measurement data values
for
various listening
positions in the preset, you can easily load one
of
them
as
necessary.
3 Turn the Ignition switch of the vehicle
to
ACC (On).
If
an
air
-conditioner
or
heater is turned on,
tum
it
off. Measurement
should
not
be
performed
if
air-conditioner
or
heater noise is present.
4 Click [Auto TCR] for [Shortcut] tab in the main menu.
The Automatic Measurement tab screen will be displayed.
When you click [Automatic Measurement]
in
the Function switching
tab, the Automatic Measurement tab screen will also be displayed.
Refer to
"O
perating the Function Switching Tab" (page
7).
5 Click [Setup] for "Auto TCR."
ALPINE
PXA-HSOO
Sound Manager
-X
FlltoF:
Shortcut t
.u
t(
HI I
~
:
i
(
r
•.
·
l
~
.
~
·
:
.u
r
~?
rr"l
t-
nl
--
~------
--
--
--
------
G
-
oTC!
~
---
>
.
,:~
;
Q
::etuu
I
Rc1u
!I
EO
I
:::
l:'
tJ
:.
6 When
the
confirmation message is displayed, check
the content and click [OK].
7 When the confirmation message is displayed again,
check the content and click [OK].
8 Click [START] in the measurement start screen.
Countdown will start.
During the 10 second countdown,
go
outside the vehicle
and close the door.
A test signal will be output from the speakers to measure the
acoustic characteristics of the cabin. Do not open any
doors until the finish message appears on the screen. If
external noise interferes with the measurement. If the error
screen is displayed, perform the measurement agai
n.
If
you want
10
slOp
measurement, click [CANCEL].
If
no microphone is connected, a confirmation message will be
displayed
and
measureme
nt
will not
be
carried out. Click [OK] to
cancel the indication.
9 When a confirmation message for closing the screen
is displayed, click [OK].
To
enable this function, Defeat should be
is
set to ON.
Mea
sur
ement
of
Auto TCR takes approximately 5 minutes.
Auto
TCR measurement r
es
ult overwrites the manual TCR
measurement result.
Sound may arrive
at
the listening position
at
slightly different times,
depending
on
the speaker and enclosure.
To
compensate
for
this, the
distance can be adjusted to be larger than the actual distanc
e.
After the setting, it is recommended to store the setting contents on
the unit. For details, refer
to
"Storing the Preset
Valu
es (Preset
Store)" (page 12).
Adjusting
for
Road
Noise
(RoadEQ)
RoadEQ (REAL-TIME OPTIMIZED ADAPTIVE DRIVlNG EQ) is a
function to automatically adjust the EQ properties in accordance with
the road noise while driving.
The Road Equalizer compensates for constantly changing noise, so
always keep the microphones connected.
1 Preparing for measurement.
Park the vehicle
in
a quiet l
oca
tion.
Close doors, windows, sunroof, etc.
Turn the air-conditioner and heater
OFF.
Turn off the engine
of
the vehicle.
2 Preparing the microphone.
Refer to the installation manual.
3 Turn the ignition switch of the vehicle
to
ACC (On).
If
an air-conditioner
or
heater is turn
ed
on, turn
it
off. Measurement
shquld not be performed
if
air-conditioner
or
heater noise is prese
nt
.
4 Click [RoadEQ] for [Shortcut] tab In the main menu.
The Automatic Measurement tab screen will be displayed.
Wh
en
you
click [Automatic Measurement] in the Function switching
tab, the Automatic Measureme
nt
tab screen will also be displayed.
Refer to "Operating the Function Switching
Tab
" (page
7).

Table of Contents

Other manuals for Alpine PXA-H800

Related product manuals