4. How to Operate Screens
4-17
(Note) Upper/Lower limit judgment value when STEPPER MODE is not OFF
The upper/lower limit judgment value set here is for the current when a
welding is performed, not for the initial setting.
Therefore, when STEPPER MODE is not OFF to perform step-up (-down) for
the initial setting, the upper/lower limit judgment value is stepped up or down
automatically.
Example) When the current is set to 2
kA, HI; 2.2
kA, LO; 1.8
kA.
When the step becomes 150%, HI and LO become as follows, and
the monitor error does not occur even when the monitored value
becomes 3.0 kA.
HI: 2.2 x 1.5 = 3.3
kA
LO: 1.8 x 1.5 = 2.7
kA