IS-300A
9. External Communication Function
9-3
(4) Protocol
Single-directional Communication Mode
(When --> is selected at COMM CONTROL in the MODE SELECT screen)
1) Monitor Data (sent after each welding)
Data strings:
!01001:m,120,1.20,0.50,00.60,20.0,200,2.00,1.50,03.00,40.0,
A B C D E F G H I J K L M
300,2.50,2.00,05.00,50.0,2,0010,5,0100,2222,555555[CR][LF]
N O P Q R S T U V W X
A Device No. Fixed to 2 digits (01 to 31)
B Schedule No. Fixed to 3 digits (001 to 255)
C Unit of monitor time m: ms C: CYC
D Monitor time of WELD1
Fixed to 3 digits (000 to 999) (ms)
Fixed to 3 digits (000 to 050) (CYC)
E Monitor current of WELD1
Fixed to 4 digits (0.00 to 9.99) (kA)
Fixed to 4 digits (00.0 to 99.9) (kA)
F Monitor voltage of WELD1 Fixed to 4 digits (0.00 to 9.99) (V)
G Monitor power of WELD1
Fixed to 5 digits (00.00 to 09.99) (kW)
Fixed to 5 digits (000.0 to 099.9) (kW)
H Monitor pulse width of WELD1 Fixed to 4 digits (10.0 to 99.9) (%)
I Monitor time of WELD2
Fixed to 3 digits (000 to 999) (ms)
Fixed to 3 digits (000 to 050) (CYC)
J Monitor current of WELD2
Fixed to 4 digits (0.00 to 9.99) (kA)
Fixed to 4 digits (00.0 to 99.9) (kA)
K Monitor voltage of WELD2 Fixed to 4 digits (0.00 to 9.99) (V)
L Monitor power of WELD2
Fixed to 5 digits (00.00 to 09.99) (kW)
Fixed to 5 digits (000.0 to 099.9) (kW)
M Monitor pulse width of WELD2 Fixed to 4 digits (10.0 to 99.9) (%)
N Monitor time of WELD3
Fixed to 3 digits (000 to 999) (ms)
Fixed to 3 digits (000 to 050) (CYC)
O Monitor current of WELD3
Fixed to 4 digits (0.00 to 9.99) (kA)
Fixed to 4 digits (00.0 to 99.9) (kA)
P Monitor voltage of WELD3 Fixed to 4 digits (0.00 to 9.99) (V)
Q Monitor power of WELD3
Fixed to 5 digits (00.00 to 09.99) (kW)
Fixed to 5 digits (000.0 to 099.9) (kW)
R Monitor pulse width of WELD3 Fixed to 4 digits (10.0 to 99.9) (%)
S STEP No. of VALVE1 Fixed to 1 digit (1 to 9)
T STEP COUNT of VALVE1 Fixed to 4 digits (0000 to 9999)
U STEP No. of VALVE2 Fixed to 1 digit (1 to 9)
V STEP COUNT of VALVE2 Fixed to 4 digits (0000 to 9999)
W WELD COUNT Fixed to 4 digits (0000 to 9999)
X TOTAL/GOOD/WORK COUNT Fixed to 6 digits (000000 to 999999)