4. How to Operate Screens
4-22
Move the cursor ( ) to the required item among (a) to (c), then press the ENTER
key; the data will be copied.
(a) IS-300A -----> MA-660A
The data in IS-300A is copied to memory of MA-660A.
When copy is complete, <END> is displayed.
Perform this operation on the source IS-300A.
(b) IS-300A <----- MA-660A
The data in memory of MA-660A is copied to IS-300A.
Perform this operation on the source IS-300A and then perform it on destination
IS-300A. After copy is complete (<END> display), wait for about 10 seconds to
turn off IS-300A.
(c) SCHEDULE [A] -----> SCHEDULE [B] - [C]
This function is used to copy the SCHEDULE (welding condition).
The Power Supply can set up to 255 schedules.
This function is also used to change from the SCHEDULE #1 setting, to perform
welding according to another schedule.
(Note) Do not operate the Program Unit until copy is complete.
For example, SCHEDULE #2 and #3 can be set by switching from
SCHEDULE #1 as follows:
SCHEDULE [A] 001 -----> SCHEDULE [B] 002
SCHEDULE [C] 003
(Be sure to press the ENTER key before moving the cursor ( ).)
Move the cursor ( ) to the following line and press the ENTER key:
SCHEDULE [A] -----> SCHEDULE [B] - [C]
The data for SCHEDULE #1 is copied to SCHEDULE #2 through this
operation. Call up #2 and #3 on the SCHEDULE screen, and change
the values, if necessary.