EasyManua.ls Logo

Amazone Pantera 4502 - Applying the Spray Liquid

Amazone Pantera 4502
292 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Using the field sprayer
Pantera 4502 CP1_E3A_E4
BAG0166.5 12.18
181
11.4.1 Applying the spray liquid
Example:
Required spray rate:
200 l/ha
Intended operational speed:
8 km/h
Nozzle type:
LU/XR
Nozzle size:
'03'
Permissible pressure range for the
spraying nozzle when fitted
min. pressure 1 bar
max. pressure 5 bar
Target spray pressure:
3.7 bar
Permissible spray pressure:
3.7 bar ±25 %
min. 2.8 bar and max. 4.6 bar
1. Prepare and stir the spray liquid correctly in
accordance with the instructions from the
crop protection agent manufacturer.
2.
Suction chest in position .
3.
Set the function selector to Spraying.
4. Adjust the additional agitator. The
stirring performance can be infinitely
adjusted.
Fig.
136
In order to achieve the maximum ap-
plication rate, switch off the additional
agitator, position 0.
The main agitator is automatically
controlled depending on the filling
level.
5. AMADRIVE: If necessary, switch on
pumps and run them at pump operating
speed.
6. Switch on the control terminal.
7. Fold out the sprayer boom.
8. Depending on the nozzles being used, set
the working height of the sprayer boom
(gap between the nozzles and the crop) ac-
cording to the spray table.
9. Enter the value for the required spray rate
in the control terminal.
10. When setting off, switch on
Spraying
on the control terminal.

Table of Contents