Using the field sprayer
Pantera 4502 CP1_E3A_E4
BAG0166.5 12.18
183
11.4.3 Dilute the spray liquid with rinsing water
The spray agent can be diluted for 2 reasons:
• To get rid of excess residual quantities.
Excess residual quantities in the spray liquid tank are initially
diluted with 10 times the quantity of flushing water to then spray
them over the field which has already been sprayed.
• Increase the stock of spray liquid to treat a remaining area.
When spreading residue, observe the maximum permissible applica-
tion quantity of the agent on areas already treated.
The spraying agent is diluted with the easy-to-use controls on the
control terminal.
The spray line is flushed on machines with nozzle control. When re-
starting the spraying, two to five minutes will elapse until the spraying
agent can be spread.
1. Control terminal:
Start dilution.
→ Flushing water is fed to the tank via the
additional agitator..
2. Observe the fill level of the tank.
3. Control terminal:
Finish dilution.
4.
Treat the remaining area,
or respectively
Apply out the excess residues on the sur-
faces already treated. Keep applying the di-
luted residues until air escapes from the
nozzles.
5. Control terminal:
Switch of spraying.
6. Cleaning the field sprayer.
Fig.
137