Using the field sprayer
192
Pantera 4502 CP1_E3A_E4 BAG0166.5
11.6.5 Exterior cleaning
1. AMADRIVE: Switch on pump if nec-
essary.
2.
Set the function selector to External
cleaning.
3. Clean the field sprayer and the sprayer
boom with the spray gun.
4.
Set the function selector to Spraying.
Fig.
146
11.6.6 Cleaning the sprayer during a critical agent change
1. Clean the sprayer in three runs as always, see page 187
2. Fill up flushing water tank.
3. Clean the sprayer, two runs, see page 187.
4. If the sprayer has been previously filled via the pressure con-
nector:
Clean the induction bowl with the spray gun and evacuate the
contents of the induction bowl.
5. Drain the final residue, see page 188.
6. By all means, clean the suction filter and pressure filter, see
page 189, 191.
7. Clean the sprayer, one run, see page 187.
8. Drain the final residue, see page 188.
11.6.7 Contact of the implement with liquid fertiliser
Liquid fertiliser that spills or escapes causes corrosion damage to the
implement, in particular to the engine and surrounding assemblies.
Clean points thoroughly with clear fresh water!