Spray table
280
Pantera 4502 CP1_E3A_E4 BAG0166.5
15 Spray table
15.1 Spray tables for flat-fan, anti-drift, injector and airmix nozzles,
spraying height 50 cm
• The spray rates [l/ha] listed in the spray tables are only valid for
water. To convert the spray rates given into AUS, multiply these
by 0.88 and, for NP solutions, by 0.85.
• Fig. 207 helps with the selection of the right nozzle type. The
nozzle type is determined by
ο the intended forward speed,
ο the required spray rate and
ο the required atomisation characteristic (fine, medium or
coarse-dropped) of the crop protection agent used for the
crop protection measure.
• Fig. 208 is used to
ο determine the nozzle size.
ο determine the required spray pressure.
ο determine the required individual nozzle output for calibrat-
ing the field sprayer.
Permissible pressure ranges for different nozzle types and sizes
Nozzle type Manufactur-
er
Permissible pressure
range [bar]
min. pres-
sure
max. pres-
sure
XRC
TeeJet 1 5
AD
Lechler 1,5 5
Air Mix
agrotop 1 6
IDK / IDKN
Lechler
1 6
IDKT
1,5 6
ID3 01 - 015
3 8
ID3 02 - 08
2 8
IDTA 120
1 8
AI
TeeJet
2 8
TTI
1 7
AVI Twin
agrotop
2 8
TD Hi Speed
2 10
For further information about the nozzle characteristics, see the noz-
zle manufacturer's website.
www.agrotop.com / www.lechler-agri.de / www.teejet.com