Cleaning, maintenance and repair
Pantera 4502 CP1_E3A_E4 BAG0166.5
13.9.1 Instructions on testing the field sprayer
• Only authorised centres are permitted to carry out spray tests.
• According to law, a spray test must be carried out:
ο 6 months after commissioning (if not performed at time of
purchase) at the latest, then
ο every two years thereafter.
Pump test - testing pump performance (delivery capacity, pressure)
Connect the test kit to the pump pressure connection.
Flow meter test
1. Remove all spray lines from the part width section valves.
2. Connect the flow meter connection to a part width section valve
and connect to the tester.
3. Block the connections for the remaining part width section valve
using blanks.
4. Switch on spraying.
Pressure gauge test
1. Remove a spray line from a part width section valve.
2. Connect the pressure gauge connection to a part width section
valve with the help of the turned socket.
3. Screw the check gauge 1/4 of an inch into the inside thread.