Cleaning, maintenance and repair
Pantera 4502 CP1_E3A_E4 BAG0166.5
13.6.21.5 Air conditioning unit in the cabin roof
Soiled units lead to reduced heating and cooling performance. Une-
conomical use of the machine.
• Observe prescribed maintenance intervals.
• With extensive dust accumulation, clean the unit more frequent-
ly.
CAUTION
Clean sensitive components with stronger compressed air or
other cleaning devices. Components will be damaged.
Do not hold the compressed air jet close to sensitive com-
ponents, such as cooling ribs or filter inserts.
Never use a steam-jet cleaning device for cleaning.
1. Unscrew the hood (Fig. 194/1) from the
cabin roof.
2. Blow out the evaporator (Fig. 195/2) and
warm water radiator (Fig. 195/3) with com-
pressed air (maximum 5 bar).
3. Renew damaged seals (Fig. 195/1) under
the cover.
4. Remount and screw on the hood.
195