Structure and function, carrier vehicle
BAG0166.5 12.18
Set the evaporator fan speed
• Automatically: Button 13; LED 10 lights up.
• Manually: Press toggle button 13; LED 11 lights up. The manu-
al fan speed is shown. You can set the desired speed using the
buttons 5 (-) and 7 (+).
Switch on ECON mode
The compressor of the air conditioner is switched off in ECON mode.
• Switch on ECON mode: Press button 14; LED 12 lights up.
The evaporator fan speed currently indicates 40% on the light
strip display (6). The evaporator fan and the heater are also con-
troller automatically in ECON mode.
• Switch on ECON mode: Select button 14.
REHEAT mode
(Defog the cabin windows)
• Switch on REHEAT mode: Press button 1; LED 3 lights up. RE-
HEAT mode is activated.
The fan speed is 1
00% and after switching the button 13, can be
controlled manually using button 5 (-) and 7 (+).
The compressor is switched on continuously in REHEAT mode
for dehumidifying the room air.
• Switch off REHEAT mode: Press button 1 again
Toggle ° Celsius / °F
• Press button 2 and 5 at the same time for approx. 3 seconds.
Pressing the buttons 2 and 5 again switches the display back to
degrees Celsius.
Malfunction / fault (displayed flashing)
Room temperature sensor fault
→ Blue Switching outputs are switched off.
Outlet air temperature sensor malfunction
→ Yellow Switching outputs are switched off
Outside air temperature sensor fault
→ Red Switching outputs are still ready for operation