EasyManua.ls Logo

Ametek CSW5550 - Figure 8-28: IEC 61000-4-13 Test Flowchart Class 1 and 2

Ametek CSW5550
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual California Instruments
CSW Series 155
Figure 8-28: IEC 61000-4-13 Test Flowchart Class 1 and 2
Start - Class 1/2
Determine appropriate test
configuration
Perform 8.2.1 Test
"Harmonic combination"
Flatcurve and Overswing
Any functional
anomalies?
No No
Class 2
required?
Meister
curve required?
Any functional
anomalies?
Any functional
anomalies?
Any functional
anomalies?
Test Completed
FAIL
Record Results
Test Completed
PASS
Record Results
Yes
Yes
No
Perform 8.2.2 Test
"Frequency Sweep"
Perform 8.2.4 Test
"Meister Curve"
Perform 8.2.3 Test
"Individual Harmonics/
Interharmonics"
Yes
Yes
No
Yes
Yes
Yes
No

Table of Contents