AMETEK CTS UCS 200N
Manual for Operation V 2.41 33 / 54
7.
Technical data
7.1.
EFT / Burst pulse 3a/3b as per ISO 7637-2
7.1.1.
Pulse specification
Open circuit
U = 25V 1000V ± 10 %
at 50 ohm
U = 13V 500V ± 10 %
Rise time (10%-90%)
5ns ± 30%
Pulse duration (10%-10%)
150ns ± 30%
Source impedance
Zq = 50 ± 20%
Polarity
Pulse 3a negative and pulse 3b positive
7.1.2.
Settings
Voltage Setting
25V 1000V in 5V steps
Burst duration
t4 = 0.1ms - 999.9ms
Burst repetition rate
t5 = 0 ms - 9,999ms / man
t5 9,999ms Auto Trigger
t5 > 9,999ms Man Trigger
Spike frequency
f = 0.1kHz - 200kHz
t1 = 5µs - 10ms
Test time
T = 0:01min - 999:59min
T > 999:59min =
Trigger
Automatic repetition of bursts
Manual trigger of one single burst
External trigger of one single burst
7.1.3.
Output
Direct
via HV coaxial connector 50
Coupling network
to +
DUT supply DC
80V / 50A / 100A / 200A
CRO Trigger
+5V rectangular trigger signal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek UCS 200N .2 Series and is the answer not in the manual?

Ametek UCS 200N .2 Series Specifications

General IconGeneral
BrandAmetek
ModelUCS 200N .2 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals