168 ASC110 / ASC130 / ASC150
3.6. Individual Operations of Maintenance
Every 2000 Hours or Every 2 Years Every 2000 Hours or Every 2 Years
Checking the oil thermometer sensor
Dismantle the sensor and clean the contact.
Dip the sensor into warm oil of known temperature and
read out the oil temperature on the thermometer.
Replace the sensor if not working properly.
Filling the hydraulic circuit:
Use a filling device with the following parameters:
min. pressure 6 MPa (870 PSI)
filtering property 3 to 10 µm
Open the cover on the right side under the cabin and
remove the cap of filling terminal.
Mount the quick coupling of the filling device to the
quick coupling.
Fill the hydraulic circuit until clean oil starts to flow out
of the hose. Collect it to a clean vessel.
After flowing out of approximately 15 l (4 US gal), close
the drain cock.
Refill oil in the tank to maximum and disconnect the
filling device.

Table of Contents