168 ASC110 / ASC130 / ASC150
3.6. Individual Operations of Maintenance
Every 2000 Hours or Every 2 Years Every 2000 Hours or Every 2 Years
Checking the oil thermometer sensor
• Dismantle the sensor and clean the contact.
• Dip the sensor into warm oil of known temperature and
read out the oil temperature on the thermometer.
Replace the sensor if not working properly.
Filling the hydraulic circuit:
• Use a filling device with the following parameters:
min. pressure 6 MPa (870 PSI)
filtering property 3 to 10 µm
• Open the cover on the right side under the cabin and
remove the cap of filling terminal.
• Mount the quick coupling of the filling device to the
quick coupling.
• Fill the hydraulic circuit until clean oil starts to flow out
of the hose. Collect it to a clean vessel.
• After flowing out of approximately 15 l (4 US gal), close
the drain cock.
• Refill oil in the tank to maximum and disconnect the
filling device.