EasyManua.ls Logo

AnsaldoSTS 95 - Figure 2-4 - Wiring Diagram for 24-Volt Systems

Default Icon
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General Maintenance and Troubleshooting
SM 6495, Rev. 7, December 2008 2-11
1A
OPTIONAL
}
2A
RESISTOR
C7/
(+)
A1
3A
C1
MCR
4A
C9/
(F2)
A7
2B
4B
5B3B
1B
TEST LINK BETWEEN 5B & 6B
NOTE 1:
DOWN IND.
NOTE 2:
ADD JUMPER 2C-6C FOR POS.
XRP OR 4B-6C FOR NEG. XRP.
DASHED WIRES INDICATE USER
SEE NOTE 4.
ADD JUMPER 2C-5C FOR GATE
(-)
R3
SNUB
RES
R1
SNUB
R2
R4
LIM
RES
CIRCUIT
AUX
BREAKER
4
1
5
6
2
RELAY
3
A
7
POWER
3C
A10
B11
(H3)
A9
(H4)
4C
C11/
B12
(B2)
C10/
2C
(B3)
C12/
(B4)
A12
A11
1C
(BRAKE)
HC
BAT
(F4)
INTERNAL
OVERLOAD
LETTERS IN PARENTHESIS ARE
FUNCTION
RELAY TERMINATIONS AS SHOWN
NOT USED
AT THIS TIME
+
HEATER
GATE DOWN
INDICATION
XRP
(SEE NOTE 1)
(SEE NOTE 2)
OPENS WITH GOLD NUT LOOSENED.
A8
MODEL 95 GATE MECHANISM,
24 VDC WIRING DIAGRAM
(H2)
C8/
_
WIRING.
NOTE 3:
2
1
BELL
0 - 89 DEG
0 - 5 DEG
5 - 93 DEG
83 - 90 DEG
46 - 93 DEG
6
3
5
4
MOTOR DN
GATE DN IND
FLASH'G LIGHT
MOTOR UP
VACANT SLOT
CLOSEDCONTACT
ARE FOR PN-150HD.
FOR NON-VITAL RELAY.
NOTE 4:
DIODE
OTOR
M
CONTROL
UP
B24
N24
8
B
6C
6B
5C
6A
5A
9
LIMIT
DIODE
UNION SWITCH & SIGNAL
UNION SWITCH & SIGNAL
645 RUSSELL ST.
BATESBURG, SC 29066
T4
T7
T5
T6
T2
T3
T1
LABEL PART NO. M46707101 / B467071 REV. 7
SPARE TERM'S
(MAY BE USED FOR ARM LIGHTS)
UG0106.0029.00
Figure 2-4 - Wiring Diagram for 24-Volt Systems

Table of Contents