EasyManuals Logo

APC Smart-UPS VT Installation

APC Smart-UPS VT
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
InstallBusbarsin523mm(20.59in)UPSSystemwiththeUPSPlacedtotheLeft
(seenfromthefront)..................................................................................................18
InstallBusbarsin523mm(20.59in)UPSSystemwiththeUPSPlacedtothe
Right(seenfromthefront)........................................................................................19
InstallBusbarsin352mm(13.85in)UPSSystemwiththeUPSPlacedtothe
Right(seenfromthefront)........................................................................................20
InstallBusbarsin352mm(13.85in)UPSSystemwiththeUPSPlacedtotheLeft
(seenfromthefront)..................................................................................................21
ConnectBatteryPowerinInstallationswithCables..........................................22
ConnectPowerCablesBetweentheUPSandtheXRBatteryEnclosure..................22
ConnectPowerCablesbetweenTwoXRBatteryEnclosures....................................23
ConnectthePowerCablestotheUPS...............................................................25
SingleFeedwithoutMBP...........................................................................................25
DualFeedwithoutMBP..............................................................................................27
PrepareforCables.......................................................................................................29
BottomCableEntry...................................................................................................29
ConnecttheACInputandACOutputCables......................................................30
SingleMains..............................................................................................................30
DualMains.................................................................................................................30
ConnecttheDCBatteryCables(ifapplicable)...........................................................31
ConnecttheCommunicationCables..................................................................32
PrepareforCommunicationCables........................................................................32
OverviewofPinConnections...................................................................................33
J106...........................................................................................................................33
EPOinSingleSystems...............................................................................................34
EPOinParallelSystems............................................................................................35
ConnectCommunicationCablesbetweenUPSandXRBattery
Enclosure.......................................................................................................................36
ConnectAPCCommunicationOptions.................................................................37
ConnectCommunicationCablesinParallelSystem..........................................38
OverviewofthePBusCables....................................................................................38
PrepareforCables.....................................................................................................39
UPSUnitsApartwithoutConduitsandInterconnection..................................40
UPSUnitsBayedTogetherwithoutConduits......................................................41
UPSUnitsApartorBayedTogetherwithConduits...........................................42
FinalMechanicalInstallation...................................................................................44
ConnectBatterySecuringBracketsforStability................................................44
ii
Smart-UPS™VT10–30kV A208/220VSingleandParallelInstallation
990–1598E-001

Table of Contents

Other manuals for APC Smart-UPS VT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the APC Smart-UPS VT and is the answer not in the manual?

APC Smart-UPS VT Specifications

General IconGeneral
Noise level55 dB
Output power24000 W
Input frequency40/70 Hz
Maximum current41 A
Output power capacity30 kVA
Emergency Power Off (EPO)Yes
Battery typeVRLA
Dimensions (WxDxH)559 x 813 x 1499 mm
Nominal input voltage400 V
CertificationC-tick, CE, EN 50091-2, EN/IEC 62040-3, IEC 61000-3-2, IEC 61000-3-3, ISO 14001, ISO 9001, VFI-SS-112
Product colorBlack
Battery recharge time5 h
Operating altitude0 - 999.9 m
Non-operating altitude0 - 15000 m
Storage temperature (T-T)-15 - 45 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Harmonized System (HS) code85078000
Weight and Dimensions IconWeight and Dimensions
Weight629090 g
Package weight660000 g