CS175-275-575-875 Installation Guide
Tone Description
One high tone for 100 mS Time remaining indicator “A “
One mid tone for 100 mS Time remaining indicator “B”
One mid tone for 100 mS, off for 100 mS, one high
tone for 100 mS
New alarm alerts for same partition
One high tone for 100 mS, off for 100 mS, one mid
tone for 100 mS, off for 100 mS, one high tone for
100 mS
New alarm alerts for different partition
Continuous on/off high tone every 100 mS; will stop
after a digit is received
System waiting for access PIN
One low tone for 200 mS (if enabled) Anti lock-up
One mid tone for 500 mS
Acknowledgement to level change
command
One mid tone for 250 mS, off for 250 mS, one mid
tone for 250 mS, off for 250 mS, one mid tone for
250 mS
Error tone
One low tone for 100mS
Relay / output turned on, or
Positive status response, or
Partition 1 armed
One low tone for 100mS; off for 200mS; one low
tone for 100 mS
Relay / output turned off, or
Negative status response, or
Partition 1 disarmed
19.5 Programming the CS534
19.5.1 Programming the CS534 parameters
All parameters are programmed via the CSx75 panel and keypad. See
Programming the
system
on page 40 for more information.
Location 0 Programming features (one segment, FSD)
1
Line hold or call back mode (Default = call back mode)
Off: the CS534 does not release the line after any communication, which
causes a listen-in session to be triggered. The listen-in session starts
immediately.
On: the CS534 releases the line and waits for the central station to call it
back before starting a listen-in session.
2
Normal two-way or listen-in only (Default = normal two-way)