46
CS175-275-575-875 Installation Guide
2. Enter a Go to program code.
3. Enter the keypad number (1-8). The Bypass LED and the Service LED blink and
the current keypad number is displayed.
4. Press . The Bypass LED flashes and the current partition is displayed.
5. Enter the partition number. The keypad automatically exits this mode.
10.3.2 Setting the starting zone
This section describes how to program the starting zone of the keypad. The zone LED
displayed on the keypad starts from the number set as the starting zone.
Steps
1. Press
92
.
2. Enter a Go to program code.
3. Enter the starting zone for the current keypad (1-32).
4. Press .
10.3.3 Setting keypad options
1. Press 93.
2. Enter a Go to program code. The Service LED blinks.
3. Turn LEDs 1-8 on or off to enable or disable the functions in the following table.
4. Press after each option.
Keypad Feature Enabled
LED1: Case Tamper on?
Reports any keypad tamper.
LED2: Silent Keypad?
Silences the entry/exit sounder and chime only.
LED3: Ding dong chime?
If off, the chime is a single tone.
LED4: 5 sec silence
Silences the pulsing keypad sounder for five
seconds when a key is pressed.
LED5: Armed zone info?
Does not allow the keypad to display faulted or
bypassed zones when the system is armed.
LED6: Beep on panics?
Sounds a short beep to verify that the keypress
was accepted.
LED7: Disable service?
Turns automatic testing of the keypad on or off.
LED8: Master keypad?
Enables temporary viewing of all partitions when
1 are pressed followed by the partition number.
10.3.4 Setting elapsed increments since last autotest
1. Press 95.