CS175-275-575-875 Installation Guide
To program a module, enter its address and press #. See
Selecting a module to
program
on page 52 for more information.
12.7 Programming via the LCD keypad
12.7.1 Entering programming mode
1. Press 8.
Enter a Go to program code.
"
You cannot enter program mode if the system or any partition is armed. The timeout for
programming mode is 15 minutes.
12.7.2 Programming a location
1. Enter the location number and press
#
.
2. Enter the new data.
3. Press to display the next segment and its data. Repeat steps 1 to 3 until you
have programmed each segment.
4. Press
#
to leave the location.
12.7.3 Discarding new data
Press the
Chime
key to delete any changes you have made to the data. The original
value is displayed.
12.7.4 Reviewing data
To review the data in a location, press and do not enter any data. Each time you press
, the programming data in the next segment is displayed.
12.7.5 Invalid data
If you attempt to program an invalid entry for a particular segment, the keypad sounder
beeps three times and the keypad display remains in the segment awaiting a valid entry.
12.7.6 Exiting a location
When you have programmed the last segment of a location, press to exit the
location and save the data.
To exit before the last segment, press #. Any changes you have made are not saved.
You can then enter another programming location.
12.7.7 Exiting programming mode
Press the Exit key to leave the current programming level and move to the
Select a
Module To Program
level.
If you do not want to program additional modules, press the Exit key again to exit
programming mode.