156
CS175-275-575-875 Installation Guide
Force arming
Arms the security system when a number of zones are open without inhibiting
each one individually. When enabled, the CSx75 can be force armed with
zones violated. Under this condition, if a force armable zone is not secure, the
Ready LED flashes. At the end of the exit delay, these zones are bypassed. If
these zones are secured any time during the arming cycle, they are
unbypassed and active in the system. If Bypass Report is enabled, the force
arming zones can be programmed to report bypass when they are force
armed (default), or to not report bypass even if Bypass Report is enabled.
See
Location 51
on page 70 and
Location 127
to
Location 206
, starting on
page 80, for more information.)
Group bypass
A designated group of zones can be programmed to bypass by pressing
Bypass-0-Bypass-Bypass prior to arming.
See
Location 127
to
Location 206
, starting on page 80, for more information.
Inhibited zones
Zones that are left open when the rest of the system is armed. They can be
entered without triggering an alarm.
Internal event Log
A list of events that have occurred in the security system. They are held in a
sequential event buffer with a time and date stamp. Up to 256 events are kept
in the rolling log. The log is never full, but overwrites the oldest entries with
new data. These events can later be viewed through downloading. All
reportable events report to the log.
Keypad activated panics
The CSx75 has three keypad activated panics that send reports to the central
station: Auxiliary 1, Auxiliary 2 and Keypad Panic. Auxiliary 1 activates the
steady siren, Auxiliary 2 sounds the keypad and Keypad Panic can be
programmed to be silent or audible (sound siren).
See
Location 34
on page 65 for more information.
Keypad sounder control
The CSx75 can be programmed to sound the keypad sounder for certain
events.
See
Location 49
on page 69 for more information.
Keypad tamper
If enabled, the CSx75 disables the keypad for 60 seconds and sends a tamper
signal to the central station if 30 keypresses are entered without producing a
valid code.
See
Location 34
on page 65 for more information.
Keyswitch
A mechanical device that can turn the system on or off without a code.
The keyswitch is normally placed outside the protected premises to effect
arming and disarming. A keyswitch must be a single pole (two-state) switch,
which is connected to a zone. It can be pulsed or normally closed.
Keyswitch arm/disarm
Any zone on the CSx75 can be programmed as a keyswitch zone. If this is
done, a momentary short on this zone arms/disarms the control. If
opening/closing reports are sent, the user code is 99.
See
Location 36
on page 67 for more information.
Keyswitch zone type
A keyswitch zone is used to arm and disarm the control unit.
Keyswitch activation immediately arms the control unit if the control unit is
disarmed. No exit time is allowed.