CS175-275-575-875 Installation Guide 69
Location 47 Partition select, zones 41 to 48 (eight segments, FSD)
This location is used to select the partition(s) in which zones 41 to 48 reside. A zone may
reside in any combination of the eight partitions. See
Location 37
on page 67 for more
information.
Location 48 Swinger shutdown count
This location contains the number of trips that can occur on a zone before that zone is
automatically bypassed.
Location 49 Keypad sounder control (one segment, FSD)
Segment 1 1
On: the keypad sounds for a telephone line cut when the
system is armed.
2
On: the keypad sounds for telephone line cut when disarmed.
3
On: the keypad sounds upon mains power failure.
4
On: the keypad sounds when a low battery is detected.
5
On: the keypad sounds during “B” Alarm trip time.
6
On: the keypad sounds for zone and box tampers.
7
Reserved
8
On: the keypad sounds for expander trouble.
Location 50 Internal siren options (three segments, FSD)
This location is used to enable siren options. There are three segments in this location.
Segment 1 1
On: the siren sounds for a telephone line cut when the system
is armed.
2
On: the siren sounds for a telephone line cut when the system
is disarmed.
3
On: the siren blasts at arming.
4
On: the siren blasts at exit expiration.
5
On: the siren blasts at closing kissoff.
6
On: the siren sounds for expander trouble.
7
On: the siren sounds for a zone or box tamper.
8
On: the siren blasts once at keyswitch or wireless arming;
twice at disarming.
Segment 2 1
On: the siren driver is a voltage output. Off: an on-board siren
driver is enabled.
2-8
Reserved
Segment 3 1-8
Reserved