94
CS175-275-575-875 Installation Guide
Location 1 Wireless sensor 1 characteristics (two segments, FSD)
This location defines the characteristics of the wireless sensors learned into zone 1.
Segment 1 1
Enable sensor (Default =on)
2
Supervised (Default =on)
3
Use Fire Supervision (Default =off)
4
Input option 1 (Default =on)
5
Input option 2 (Default =off)
6-8
Reserved
Segment 2 1
Partition 1 keyfob (Default =on)
2
Partition 2 keyfob (Default =on)
3
Partition 3 keyfob (Default =on)
4
Partition 4 keyfob (Default =on)
5
Partition 5 keyfob (Default =on)
6
Partition 6 keyfob (Default =on)
7
Partition 7 keyfob (Default =on)
8
Partition 8 keyfob (Default =on)
Location 2 to 168 Wireless sensor 2 to 168 characteristics (two segments, FSD)
These locations define the characteristics of the wireless sensors learned into zone 2 to
168. The information in these segments is the same as the information in location 1, zone
1.
Location 169 to 192 Reserved
Location 193 Receiver features (one segment,FSD)
Segment 1 1
On: enables jam detection.
2
On: enables sequential programming method.
3
Keyfob user ID (default = off).
Off: all keyfobs report to the panel as user 99.
On: keyfobs report as the learned zone.
4
Enable antenna tamper, reports as box tamper (Default = Off).
5
Case tamper enabled.
6-8
Reserved