Cards 1&2: Wrong file system Both SxS PRO cards are not
formatted in the file system
required by the camera. Format
the cards.
Cards 1&2: Rec protected Both SxS PRO cards are rec-
protected. Eject the cards, switch
off the protection and re-insert
the cards.
Camera overheating The camera is getting too warm.
Apply additional cooling or shut
down to prevent hardware
damage.
Low sensor temperature Sensor temperature is out of
range. Wait until error message
disappears before continuing to
shoot.
High sensor temperature Sensor temperature is out of
range. Wait until error message
disappears before continuing to
shoot.
System error Reboot the camera.
Codec error. Reboot. An error in the compression
module has occured, and
recording was aborted. Reboot
the camera before you continue
to record!
Sensor error. Reboot. The image sensor has a
problem. reboot the camera.
Sensor boot error The sensor has not booted.
Reboot the camera.
Interface error. Reboot. An internal data interface has a
problem. If rebooting does not
solve the problem, contact the
ARRI service.
Fan error. Contact service. The fan module is not working
properly. Either install an SFM-1,
or contact the ARRI service.
Fatal system error. Shut down
camera.
Camera has to be rebooted. If
this error continues to occur, a
hardware problem might be the
reason. Contact the ARRI
service.
Sync clock out of range. The sync signal clock does not
match the camera setting. Make
sure the settings match!
Syncing sensor Slave camera syncs to master
camera. Wait until message
disappears before starting to
record!