67
Switching On and Off the Warning Signal for
Asynchronous Running (Mode 6)
Standby Operation
• Change from Mode 1 to Mode 6 by depressing the
“MODE”-button five times (or three times if no functional
expansion module is attached).
• By depressing the “SEL”-button twice, activate the display
for setting the warning signal.
• Within three seconds, depress the “SET”-button to
select one of the four settings.
• Depressing the “MODE”-button confirms the selection
and changes the display back to Mode 1.
Display Warning tone on start Warning tone on stop
LS _ _ off off
LS – _ on off
LS _ – off on
LS – – on on
Setting the Volume of the Warning Signal
• Change from Mode 1 to Mode 6 by depressing the
“MODE”-button five times (or three times if no functional
expansion module is attached).
• Depress the “SEL”-button three times to activate the
display for setting the warning signal volume.
• Select the desired volume with the “SET”-button.
At volume level 0 the acoustic TC-warning is also
switched off.
0…off
3…maximum volume
Camera Operation
Note: When the camera exits the motion control
mode because of a fault, a permanent beep will
occur until the camera is restarted or the error
was checked in the motion control error menu.