26
6. When all values are entered Click Verify. Then press Cycle Start. The wires should now be
1270m (50in)
7. Use the Green check to exit. Your Average number should appear in the Length Calibration
window.
SlipSensitivity.(0‐20)
Slip sensitivity is used when the machine is equipped with the “Slip and Snag Detector” option or
this machine is built with a wire measuring encoder. When this is set for 1 or higher the machine
will compare the motion of the wire with the motion of the infeed motor. The slip sensitivity
setting determines the allowable differential. 0 = no detection, 20 = max sensitivity.
MaxSlug.
This is the maximum length of the scrap slug. If the strip length is greater than this setting the end
will be stripped in multiple cuts. This happens when the nibble function is selected in Machine
Configuration.
Color.
This allows the wire image to be display in it actual color. Check “Dual Color” to display a stripe
on the wire. Core or conductor color can also be displayed.
Largewirecheckbox