9
D. MACHINE SIZE:
Length: 50” (1520 mm)
Width: 24” (605 mm)
Height: 57” (1453 mm)
E. MACHINE WEIGHT:
2200 lbs. (998 Kg.) packed weight
F. Electrical
230±10% VAC 47-63 Hz. Single Phase 3 kW (Nominal)
Protection Against Electric Shock: Grounded metal enclosure
G. Environmental
Temperature: Operating 0°C to +45°C, Storage -25°C to +55°C
Relative Humidity: 30% to 95% (non- condensing)
Altitude: Up to 4000 ft. MSL (1200 m MSL)
Sound Level: 54 dbA quiescent 73 dbA automatic cycle
Other:
This equipment is designed for normal operation in a dry location where it is not likely to be
subjected to drip, splash or spray of water or other liquid.
INSTALLATION
A. Once you have received your CS 327, un-crate the unit and make a thorough inspection to determine
if any loss of contents, or damage, has occurred during shipping. Any shipping related damage must
be reported to the carrier immediately.
B. This equipment is designed for normal operation in a dry location where it is not likely to be subjected
to drip, splash or spray of water or other liquids. Select a suitable location for which allows adequate
perimeter access for maintenance.
C. Un-pack the LCD screen and mount it on the monitor bracket.
D. Un-pack the keyboard and mouse. Along with the computer you will find the manual and operating
system disks for the PC. (Store these items along with the carton in a safe location. In the event of a
computer failure it will be necessary to return it along with the operating system disks in the original
carton.) Set the keyboard and mouse on the operator station if they are not already installed. The two
devices route into the operator station and plug into the monitor.
E. The PC is placed in the compartment at the left end of the lower cabinet. Use the provided foot to
stand the PC vertically. Connect the cables as marked and slide it in place.