CONFIGURATION MANUAL
Ascom d83 DECT Handset
Handset Configuration
4. Select System Profiles System Profiles Sub Groups Alarm settings group Alarm settings X
Alarm on long press.
Alarm type for long press - Determines the alarm type to be sent when long pressing the alarm
button. If Not used is selected, the call can still be dialed after alarm number (if any, see 5.27
Common Alarm Settings, page 37) without sending an alarm.
ALS - Determines if a ramped up signal shall sound after an alarm is sent
If the handset is configured to call a predefined number when an alarm is sent (see 5.27
Common Alarm Settings, page 37), the ALS is not triggered.
5. Select System Profiles System Profiles Sub Groups Alarm settings group Alarm settings X
Alarm on multiple press.
Alarm type for long press - Determines the alarm type to be sent when long pressing the alarm
button. If Not used is selected, the call can still be dialed after alarm number (if any, see 5.27
Common Alarm Settings, page 37) without sending an alarm.
ALS - Determines if a ramped up signal shall sound after an alarm is sent
If the handset is configured to call a predefined number when an alarm is sent (see 5.27
Common Alarm Settings, page 37), the ALS is not triggered.
6. Select System Profiles System Profiles Sub Groups Alarm settings group Alarm settings X
No-movement and Man-down.
Man-down alarm - Determines if the Man-down alarm is enabled or disabled.
Man-down detection time - Determines when the warning phase starts after man-down is triggered.
No-movement alarm - Determines if the No-movement alarm is enabled or disabled.
No-movement detection time - Determines when the warning phase starts after No-movement alarm
is triggered.
Warning phase duration - Determines the time before the warning phase is ended and the alarm is
sent.
ALS - Determines if a ramped up signal shall sound after an alarm is sent
If the handset is configured to call a predefined number when an alarm is sent (see 5.27
Common Alarm Settings, page 37), the ALS is not triggered.
7. Select System Profiles System Profiles Sub Groups Alarm settings group Alarm settings X
Pull-cord.
Used pull-cord alarm - Determines if the pull-cord alarm is enabled or disabled.
ALS - Determines if a ramped up signal shall sound after an alarm is sent
If the handset is configured to call a predefined number when an alarm is sent (see 5.27
Common Alarm Settings, page 37), the ALS is not triggered.
5.45.2.3 Configure Sound and Alerts Sub Group
These parameters let the system administrator define up to five different system profile sub groups of
sounds and alerts. To configure a sub group:
1. Select System Profiles System Profiles Sub Groups Sound and alerts group Sound and alerts X
2. In the Name of group field, either accept the default name Group X or enter a description appropriate
to this particular sub group of sounds and alerts.
TD 93426EN / 28 January 2022 / Ver. C
57

Table of Contents

Other manuals for ASCOM d83

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ASCOM d83 and is the answer not in the manual?

ASCOM d83 Specifications

General IconGeneral
BrandAscom
Modeld83
Caller IDYes
SpeakerphoneYes
Answering MachineNo
Battery LifeUp to 200 hours standby
Number of Handsets1
RangeUp to 300 meters outdoors

Related product manuals