6.1.2 Message
Step 1: "Drag n' drop" the selected
device from the Device List.
Step 2: Double click the device to
open "DSP Configuration" window.
"Drag n' Drop" the Message Player
component to the window, and
connect the component to the Network
Paging component(The channel 2 as
the message input channel for
example).
Step 3: Double click the Network
Paging component to open its setting
window.
1. Click [Activation] button on
channel 2.
2. Click [Paging Events] button.
3. Click [Add] button.
4. Select [Singular].
5. Enter the name of singular
message event.