send to the engineers.
Fan Error
Fan fail
Replace the fan
3.1.9.1.1 Ethernet Broken
The Ethernet connection fails(if the Ethernet monitoring has been enabled in Aties Studio).
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
A text message displays at the touch screen of the IDA8C:
"Ethernet Broken."
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Troubleshooting:
Check the Ethernet cable. Once it's recovered, in the LOG page the touch screen shows:
"Ethernet Recovery."
3.1.9.1.2 User Define Error
A user defined error is detected by the IDA8C/S. This kind of error can be defined by using the "Fault
Definer" DSP component.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of IDA8C/S.
Log:
The text messages display at the touch screen of IDA8C:
"User Define Error"
"XXXXX", where XXXXX is the content defined in "Fault Definer" the DSP component
field [Message].
A text message displays at the window [Machine Fault Record] in Ateis Studio: