Avertissements Installation
8080
Warnings Installation
If the unit is set up in a suspended ceiling or attic, or above living
space, a drain pan must be installed underneath the water
heater. A drainage device connected to a drain is required.
ELECTRICAL CONNECTION:
Be sure to turn o󰀨 the power before removing the cover, to
prevent any risk of injury or electric shock.
Upstream of the unit, the electrical installation must have
an all-pole cut-out device (circuit breaker, fuse) compliant
with the local installation rules in force (30 mA residual cur-
rent device).
Earthing is mandatory. A special terminal marked
is
provided for this purpose.
Refer to the wiring diagrams in the manual.
The electrical installation must be constructed in accor-
dance with the applicable regulations.
This unit is designed to operate at a nominal voltage of 230
volts 50 Hz. The voltage at the unit's terminals must never
drop below 198 V or exceed 264 V (including during the
starting stages).
The maximum cable length depends on the voltage drop,
which must be less than 2 %. Use a larger cable cross-
section if the voltage drop is 2 % or more.
The electrical connections must only be made once all the
other installation operations (mounting, assembly, etc.)
have been completed.
Check that the wiring is not subject to wear, corrosion,
excessive pressure, vibration, sharp edges or any other
harmful environmental conditions.