User's Manual 6. Configuration Using the Web Interface
Version 6.6 125 MediaPack Series
6.6.1.1.3 Saving Configuration
Changes made on the Web interface are volatile (in RAM). Changes to parameters with
on-the-fly capabilities are immediately available, while other parameters (preceded by the
lightning symbol) are updated only after a device reset. Parameters that are only saved
to the volatile memory, revert to their previous settings after a power failure or hardware
reset.
To save changes so they are available after a power failure, you must save the changes to
the non-volatile memory (flash). When the configuration is saved, all parameters and
loaded files are saved to the non-volatile memory.
To save the changes to the non-volatile memory:
1. Open the 'Maintenance Actions' page (refer to Maintenance Actions on page 122).
2. Under the 'Save Configuration' group, click BURN; a confirmation message appears
when the configuration successfully saves.
Notes:
Saving configuration to the non-volatile memory may disrupt traffic on the
device. To avoid this, disable all new traffic before saving, by performing
a graceful lock (refer to Locking and Unlocking the Device on page 124).
Throughout the Web interface, parameters preceded by the lightning
symbol are not applied on-the-fly to the device and require that you reset
the device (refer to Resetting the Device on page 123) for them to take
effect.