User's Manual 1132 Document #: LTRT-27045
Mediant 1000B Gateway & E-SBC
Parameter Description
Note: The parameter can be configured for a Tel Profile.
[EnablePulseDialDetection] Enables the device to detect pulse (rotary) dialing from analog
equipment (e.g., telephones) connected to the device's FXS
port interfaces.
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
Note: For the parameter to take effect, a device reset is
required.
[EnablePulseDialGeneration] Enables pulse dialing generation to the analog side (FXO)
when dialing is received from the IP side.
ï‚§ [0] Disable = (Default) Device generates DTMF signals to
the FXO side.
ï‚§ [1] Enable = Device generates pulse dialing to the FXO
side.
Note: For the parameter to take effect, a device reset is
required.
[PulseDialGenerationBreakTime] Defines the duration of the Break connection (off-hook) for
FXO pulse dial generation.
The valid value range is 20 to 120 (in msec). The default is 60.
Note: For the parameter to take effect, a device reset is
required.
[PulseDialGenerationMakeTime] Defines the duration of the Make connection (on-hook) for
FXO pulse dial generation.
The valid value range is 20 to 120 (in msec). The default is 40.
Note: For the parameter to take effect, a device reset is
required.
[PulseDialGenerationInterDigitTime] Defines the inter-digit duration (time between consecutively
dialed digits) for FXO pulse dial generation.
The valid value range is 300 to 1500 (in msec). The default is
700.
Note: For the parameter to take effect, a device reset is
required.
62.10.12 Trunk Groups and Routing Parameters
The routing parameters are described in the table below.
Table 62-67: Routing Parameters
Parameter Description
Trunk Group Table
Trunk Group Table
configure voip > gateway trunk-
group
[TrunkGroup]
Defines and activates Trunk Groups.
The format of the ini file table parameter is as follows:
[TrunkGroup]
FORMAT TrunkGroup_Index = TrunkGroup_TrunkGroupNum,
TrunkGroup_FirstTrunkId, TrunkGroup_FirstBChannel,
TrunkGroup_LastBChannel, TrunkGroup_FirstPhoneNumber,