Version 7.2 927 Mediant 1000B Gateway & E-SBC
User's Manual 62. Configuration Parameters Reference
62 Configuration Parameters Reference
The device's configuration parameters, default values, and their descriptions are
documented in this section.
Note: Parameters and values enclosed in square brackets [...] represent the ini file
parameters and their enumeration values.
62.1 Management Parameters
This section describes the device's management-related parameters.
62.1.1 General Parameters
The general management parameters are described in the table below.
Table 62-1: General Management Parameters
Parameter Description
[WebLoginBlockAutoComplete]
Disables autocompletion when entering the management login
username in the 'Username' field of the device's Web interface.
Disabling autocompletion may be useful for security purposes by
hiding previously entered usernames and thereby, preventing
unauthorized access to the device's management interface.
ï‚§ [0] Disable = (Default) Autocompletion is enabled and the
'Username' field automatically offers previously logged in
usernames.
ï‚§ [1] Enable = Autocompletion is disabled.
[EnforcePasswordComplexity] Enables the enforcement of management login-password
complexity requirements to ensure strong passwords.
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
For more information on password complexity requirements, see the
'Password' parameter in Configuring Management User Accounts
on page 65.
Access List Table
configure network >
access-list
[WebAccessList_x]
This table configures up to ten IP addresses that are permitted to
access the device's Web interface and Telnet interfaces. Access
from an undefined IP address is denied. When no IP addresses are
defined in this table, this security feature is inactive (i.e., the device
can be accessed from any IP address).
The default is 0.0.0.0 (i.e., the device can be accessed from any IP
address).
For example:
WebAccessList_0 = 10.13.2.66
WebAccessList_1 = 10.13.77.7
For a description of the parameter, see ''Configuring Web and
Telnet Access List'' on page 73.

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals