Version 7.2 65 Mediant 1000B Gateway & E-SBC
User's Manual 6. Web-Based Management
6.2 Configuring Management User Accounts
The Local Users table lets you configure up to 10 management user accounts for the
device's Web interface and CLI. You configure each user account with login credentials
(username and password) and with a management user level which defines the level of
read and write privileges. The table below describes the different types of user levels:
Table 6-5: Description of Management User Levels
User Level
Numeric
Representation in
RADIUS
Privileges
Security
Administrator
200 Read/write privileges for all Web pages. This user level
can create all other user levels and is the only one that
can create the first Master user.
Note: At least one Security Administrator user must exit.
Master
220 Read/write privileges for all Web pages. This user level
can create all user levels, including additional Master
users and Security Administrators. It can delete all users
except the last Security Administrator.
Note: Only Master users can delete Master users. If only
one Master user exists, it can be deleted only by itself.
Administrator
100 Read/write privileges for all Web pages, except security-
related pages and the Local Users table where this user
has read-only privileges.
Monitor
50 Read-only privileges and access to security-related pages
is blocked.
Note: Only Security Administrator and Master users can configure users in the Local
Users table. Administrator users have read-only privileges and Monitor users are
denied access to the table. However, Administrator and Monitor users can change
their login credentials in the Web Settings page (see ''Configuring Web Session and
Access Settings'' on page 70).
By default, the device is pre-configured with the following two user accounts:
Table 6-6: Default User Accounts
User Level Username
(Case-Sensitive)
Password
(Case-Sensitive)
Security Administrator
"Admin" "Admin"
Monitor
"User" "User"

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals