EasyManuals Logo

AudioCodes MSBG Series User Manual

AudioCodes MSBG Series
1195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #899 background imageLoading...
Page #899 background image
Version 7.2 899 Mediant 1000B Gateway & E-SBC
User's Manual 56. Self-Testing
56 Self-Testing
The device features the following self-testing modes to identify faulty hardware
components:
Detailed Test (Configurable): This test verifies the correct functioning of the different
hardware components on the device. This test is done when the device is taken out of
service (i.e., not in regular service for processing calls). The test is performed on
startup when initialization of the device completes.
To enable this test, set the ini file parameter, EnableDiagnostics to 1 or 2, and then
reset the device. Upon completion of the test and if the test fails, the device sends
information on the test results of each hardware component to the Syslog server.
The following hardware components are tested:
DSPs - when EnableDiagnostics = 1 or 2
Analog interfaces - when EnableDiagnostics = 1 or 2
Note:
To return the device to regular operation and service, disable the test by setting
the ini file parameter, EnableDiagnostics to 0, and then reset the device.
While the test is enabled, ignore errors sent to the Syslog server.
Startup Test (automatic): This hardware test has minor impact in real-time. While
this test is executed, the regular operation of the device is disabled. If an error is
detected, an error message is sent to the Syslog.

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals