User's Manual 264 Document #: LTRT-27045
Mediant 1000B Gateway & E-SBC
2. Click New; the following dialog box appears:
Figure 15-40: Remote Web Services Table - Add Dialog Box
3. Configure a remote Web service according to the parameters described in the table
below.
4. Click Apply, and then save your settings to flash memory.
Table 15-18: Remote Web Services Table Parameter Descriptions
Parameter Description
General
Index
[HTTPRemoteServices_Index]
Defines an index number for the new table row.
Note:
ï‚§ Each row must be configured with a unique index.
ï‚§ The parameter is mandatory.
Name
rest-name
[HTTPRemoteServices_Name]
Defines an arbitrary name to easily identify the row.
The valid value is a string of up to 40 characters.
Note:
ï‚§ Each row must be configured with a unique name.
ï‚§ The parameter is mandatory.
Type
rest-message-type
[HTTPRemoteServices_HTTPT
ype]
Defines the type of service provided by the HTTP remote host:
ï‚§ [0] Routing (default) = Routing service (also includes Call Status
and Topology Status).
ï‚§ [1] Call Status = Call status service.
ï‚§ [2] Topology Status = Topology status service (e.g., change in
configuration).
ï‚§ [3] Capture = Recording of signaling and RTP packets, which
can be sent to a remote host, for example, to a Syslog server or
AudioCodes SEM.
Note:
ï‚§
You can configure only one remote Web service for each of the

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals