 To configure a Malicious Signature:
1. Open the Malicious Signature table (Setup menu > Signaling & Media tab > SBC
folder > Malicious Signature).
2. Click New; the following dialog box appears:
Figure 36-1: Malicious Signature Table - Add Dialog Box
3. Configure a Malicious Signature according to the parameters described in the table
below.
4. Click Apply.
Table 36-1: Malicious Signature Table Parameter Descriptions
Parameter Description
Index
[ConditionTable_Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Name
name
[MaliciousSignatureDB_Name]
Defines an name to easily identify the row.
The valid value is a string of up to 30 characters.
Note: Each row must be configured with a unique name.
Pattern
pattern
[MaliciousSignatureDB_Pattern]
Defines the signature pattern.
The valid value is a string of up to 60 characters.
Note: The parameter is mandatory.