EasyManuals Logo

AudioCodes MSBG Series User Manual

AudioCodes MSBG Series
1195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #702 background imageLoading...
Page #702 background image
User's Manual 702 Document #: LTRT-27045
Mediant 1000B Gateway & E-SBC
 To configure a Malicious Signature:
1. Open the Malicious Signature table (Setup menu > Signaling & Media tab > SBC
folder > Malicious Signature).
2. Click New; the following dialog box appears:
Figure 36-1: Malicious Signature Table - Add Dialog Box
3. Configure a Malicious Signature according to the parameters described in the table
below.
4. Click Apply.
Table 36-1: Malicious Signature Table Parameter Descriptions
Parameter Description
Index
[ConditionTable_Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Name
name
[MaliciousSignatureDB_Name]
Defines an name to easily identify the row.
The valid value is a string of up to 30 characters.
Note: Each row must be configured with a unique name.
Pattern
pattern
[MaliciousSignatureDB_Pattern]
Defines the signature pattern.
The valid value is a string of up to 60 characters.
Note: The parameter is mandatory.

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals