User's Manual 882 Document #: LTRT-27045
Mediant 1000B Gateway & E-SBC
Note:
• If you want to configure a Log Filter rule that logs Syslog messages to a Syslog
server (i.e., not to a Debug Recording server), you must enable Syslog
functionality, using the 'Enable Syslog' (EnableSyslog) parameter (see ''Enabling
Syslog'' on page 892). Enabling Syslog functionality is not required for rules that
include Syslog messages in the debug recording sent to the Debug Recording
server.
• To configure the Syslog server's address, see ''Configuring the Syslog Server
Address'' on page 892. To configure additional, global Syslog settings, see
''Configuring Syslog'' on page 886.
• To configure the Debug Recording server's address, see ''Configuring the Debug
Recording Server Address'' on page 896.
• To configure additional, global CDR settings such as at what stage of the call the
CDR is generated (e.g., start and end of call), see ''Configuring CDR Reporting''
on page 869.
The following procedure describes how to configure Log Filter rules through the Web
interface. You can also configure it through ini file (LoggingFilters) or CLI (configure
troubleshoot > logging logging-filters).
 To configure a Log Filter rule:
1. Open the Logging Filters table (Troubleshoot menu > Troubleshoot tab > Logging
folder > Logging Filters).
2. Click New; the following dialog box appears:
Figure 55-1: Logging Filters Table - Add Dialog Box
3. Configure a Log Filtering rule according to the parameters described in the table
below.
4. Click Apply.
Table 55-1: Logging Filters Table Parameter Descriptions
Parameter Description
Index
[LoggingFilters_Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.