2. Click New; the following dialog box appears:
Figure 59-1: Test Call Rules Table - Add Dialog Box
3. Configure a test call according to the parameters described in the table below.
4. Click Apply, and then save your settings to flash memory.
Table 59-1: Test Call Rules Table Parameter Descriptions
Parameter Description
Common
Index Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Endpoint URI
endpoint-uri
[Test_Call_EndpointURI]
Defines the endpoint's URI. This can be defined as a user or
user@host. The device identifies this endpoint only by the URI's
user part. The URI's host part is used in the SIP From header in
REGISTER requests.
The valid value is a string of up to 150 characters. By default, the
parameter is not configured.
Note: The parameter is mandatory.
Called URI
called-uri
[Test_Call_CalledURI]
Defines the destination (called) URI (user@host).
The valid value is a string of up to 150 characters. By default, the
parameter is not configured.
Route By
route-by
[Test_Call_RouteBy]
Defines the type of routing method. This applies to incoming and
outgoing calls.
ï‚§ [0] Tel-to-IP = Calls are matched by a Tel-to-IP routing rule in the
Tel-to-IP Routing table (see Configuring Tel-to-IP Routing Rules
on page 475).

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals