EasyManuals Logo

AudioCodes MSBG Series User Manual

AudioCodes MSBG Series
1195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #909 background imageLoading...
Page #909 background image
Version 7.2 909 Mediant 1000B Gateway & E-SBC
User's Manual 59. Testing SIP Signaling Calls
Parameter Description
test-mode
[Test_Call_TestMode]
ï‚§
[0] Once = (Default) The test runs until the lowest value between
the following is reached:

Maximum channels is reached for the test session,
configured by 'Maximum Channels for Session'.

Call duration ('Call Duration') multiplied by calls per second
('Calls per Second').

Test duration expires, configured by 'Test Duration'.
ï‚§ [1] Continuous = The test runs until the configured test duration
is reached. If it reaches the maximum channels configured for
the test session (in the 'Maximum Channels for Session'), it waits
until the configured call duration of a currently established tested
call expires before making the next test call. In this way, the test
session stays within the configured maximum channels.
Note: The parameter is applicable only if you configure 'Call Party'
to Caller.
Test Duration
test-duration
[Test_Call_TestDuration]
Defines the test duration (in minutes).
The valid value is 0 to 100000. The default is 0 (i.e., unlimited).
Note: The parameter is applicable only if you configure 'Call Party'
to Caller.
Play
play
[Test_Call_Play]
Enables and defines the playing of a tone to the answered side of
the call.
ï‚§ [0] Disable
ï‚§ [1] DTMF = (Default) Plays a user-defined DTMF string,
configured in ''Configuring DTMF Tones for Test Calls'' on page
913.
ï‚§ [2] PRT = Plays a non-DTMF tone from the PRT file (Dial Tone
2). For this option, you must load a PRT file to the device (see
''Prerecorded Tones File'' on page 744).
Note:
ï‚§ To configure the DTMF signaling type (e.g., out-of-band or in-
band) use the 'DTMF Transport Type' parameter (see
''Configuring DTMF Transport Types'' on page 191).
ï‚§ The parameter is applicable only if you configure 'Call Party' to
Caller
.
Schedule Interval
schedule-interval
[Test_Call_ScheduleInterval]
Defines the interval (in minutes) between automatic outgoing test
calls.
The valid value range is 0 to 100000. The default is 0 (i.e.,
scheduling is disabled).
Note: The parameter is applicable only if you configure 'Call Party'
to Caller.

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals